詳細說明
| 氣體/傳感器 |
量程 |
默認分辨率 |
高分辨率 |
TWA***
|
STEL*** |
低報*** |
高報*** |
| O2 |
0-30.0% |
0.50% |
N/A |
N/A |
N/A |
19.5 |
23.5 |
| H2S |
0-500 X10-6 |
1.0X10-6 |
N/A |
10 |
15 |
10 |
15 |
| CO |
0-999 X10-6 |
1.0 X10-6 |
N/A |
35 |
50 |
35 |
200 |
| 雙毒氣(H2S) |
0-500 X10-6 |
1.0 X10-6 |
N/A |
10 |
15 |
10 |
15 |
| 雙毒氣(CO) |
0-500 X10-6 |
1.0 X10-6 |
N/A |
35 |
50 |
35 |
200 |
| PH3 |
0-5.0 X10-6 |
1.0 X10-6 |
0.1 X10-6 |
0.3 |
1.0 |
0.3 |
1.0 |
| SO2 |
0-150 X10-6 |
1.0 X10-6 |
0.1 X10-6 |
2 |
5 |
2 |
5 |
| NO2 |
0-99.9 X10-6 |
1.0 X10-6 |
0.1 X10-6 |
2.0 |
5.0 |
2.0 |
5.0 |
| HCN |
0-30.0 X10-6 |
1.0 X10-6 |
0.1 X10-6 |
4.7 |
10.0 |
4.7 |
10.0 |
| CL2 |
0-50.0 X10-6 |
1.0 X10-6 |
0.1 X10-6 |
0.5 |
1.0 |
0.5 |
1.0 |
| NH3 |
0-100 X10-6 |
1.0 X10-6 |
0.1 X10-6 |
25 |
35 |
25 |
50 |
| CLO2 |
0-1.00 X10-6 |
0.1 X10-6 |
0.01X10-6 |
0.1 |
0.3 |
0.1 |
0.3 |
| O3 |
0-1.00 X10-6 |
0.1 X10-6 |
0.01X10-6 |
0.1 |
0.1 |
0.1 |
0.1 |
| CO2/IR |
0-50,000 X10-6 |
50 X10-6 |
N/A |
5,000 |
30,000 |
5,000 |
30,000 |
| |
0-5.0% v/v |
0.01% |
N/A |
0.5% |
3.0% |
0.5% |
3.0% |
| VOC/PID |
0-1000 X10-6 |
1 X10-6 |
N/A |
50 |
100 |
50 |
100 |
| LEL |
0-100% LEL |
1% |
N/A |
N/A |
N/A |
10% |
20%
|
| |
0-5.0% v/v |
0.1% |
N/A |
N/A |
N/A |
0.5% |
1.0% |
| 應 用 |
便攜式五合一氣體檢測儀保護作業人員免受毒氣侵害 |
| 傳感器配置 * |
一個氧氣,一個可燃氣,一個毒氣(可以是雙毒氣CO/H2S傳感器或其他);最后一個可為毒氣,PID 或IR任選一個 |
| 顯 示 |
常規LCD,背景燈:弱光(自動),報警狀態(自動),需要時再次激活 |
| 重量 |
370g |
| 規格 |
14.5 x 7.4 x 3.8cm |
| 電池 |
三節AA電池工作14小時(電動氣泵工作10小時) |
| 充電電池 |
工作16小時(電動氣泵工作10小時) |
| 聲音報警 |
聲音警報在各種脈沖時距離30厘米為95 dB |
| 震動報警 |
脈沖警報或任何狀況警報 |
| 可視報警 |
2個閃光報警燈 |
| 傳感器類型 |
電化學,催化燃燒及可選紅外或PID |
| 校準 |
自動(單獨或與MicroDock II連接) |
| 數據記錄 |
所有發生事件(零點校正,校準標氣調整,氣體讀數,TWA, STEL,報警狀況,微處理器探測到的失誤) |
| 安全特性 |
X5 及X5PID:Ⅱ1G Ga Exia ⅡC T4 ATEX; Ga Exia ⅡC T4 IECEx
X5IR CO2:Ⅱ 2 G Ga Ex d ia ⅡC T4 ATEX; Ga Ex d ia ⅡC T4 IECEx
美國和加拿大認證:Class,Div.1 Gr.A,B,C,D T4.
CAN/CSA C22.2 No.152 ;ANSI ISA S12.13.1 |
| 保修期 |
一年
|
推薦產品
掃碼加銷售專員微信
氣體檢測儀
??????13241854077
|