公司基本資料信息
![]() |
||||||||||||||||||||||||||||||
| 氣體/傳感器 | 量程 | 默認分辨率 | 高分辨率 |
TWA*** |
STEL*** | 低報*** | 高報*** |
| O2 | 0-30.0% | 0.50% | N/A | N/A | N/A | 19.5 | 23.5 |
| H2S | 0-500 X10-6 | 1.0X10-6 | N/A | 10 | 15 | 10 | 15 |
| CO | 0-999 X10-6 | 1.0 X10-6 | N/A | 35 | 50 | 35 | 200 |
| 雙毒氣(H2S) | 0-500 X10-6 | 1.0 X10-6 | N/A | 10 | 15 | 10 | 15 |
| 雙毒氣(CO) | 0-500 X10-6 | 1.0 X10-6 | N/A | 35 | 50 | 35 | 200 |
| PH3 | 0-5.0 X10-6 | 1.0 X10-6 | 0.1 X10-6 | 0.3 | 1.0 | 0.3 | 1.0 |
| SO2 | 0-150 X10-6 | 1.0 X10-6 | 0.1 X10-6 | 2 | 5 | 2 | 5 |
| NO2 | 0-99.9 X10-6 | 1.0 X10-6 | 0.1 X10-6 | 2.0 | 5.0 | 2.0 | 5.0 |
| HCN | 0-30.0 X10-6 | 1.0 X10-6 | 0.1 X10-6 | 4.7 | 10.0 | 4.7 | 10.0 |
| CL2 | 0-50.0 X10-6 | 1.0 X10-6 | 0.1 X10-6 | 0.5 | 1.0 | 0.5 | 1.0 |
| NH3 | 0-100 X10-6 | 1.0 X10-6 | 0.1 X10-6 | 25 | 35 | 25 | 50 |
| CLO2 | 0-1.00 X10-6 | 0.1 X10-6 | 0.01X10-6 | 0.1 | 0.3 | 0.1 | 0.3 |
| O3 | 0-1.00 X10-6 | 0.1 X10-6 | 0.01X10-6 | 0.1 | 0.1 | 0.1 | 0.1 |
| CO2/IR | 0-50,000 X10-6 | 50 X10-6 | N/A | 5,000 | 30,000 | 5,000 | 30,000 |
| 0-5.0% v/v | 0.01% | N/A | 0.5% | 3.0% | 0.5% | 3.0% | |
| VOC/PID | 0-1000 X10-6 | 1 X10-6 | N/A | 50 | 100 | 50 | 100 |
| LEL | 0-100% LEL | 1% | N/A | N/A | N/A | 10% | 20% |
| 0-5.0% v/v | 0.1% | N/A | N/A | N/A | 0.5% | 1.0% |
| 應 用 | 便攜式五合一氣體檢測儀保護作業人員免受毒氣侵害 |
| 傳感器配置 * | 一個氧氣,一個可燃氣,一個毒氣(可以是雙毒氣CO/H2S傳感器或其他);最后一個可為毒氣,PID 或IR任選一個 |
| 顯 示 | 常規LCD,背景燈:弱光(自動),報警狀態(自動),需要時再次激活 |
| 重量 | 370g |
| 規格 | 14.5 x 7.4 x 3.8cm |
| 電池 | 三節AA電池工作14小時(電動氣泵工作10小時) |
| 充電電池 | 工作16小時(電動氣泵工作10小時) |
| 聲音報警 | 聲音警報在各種脈沖時距離30厘米為95 dB |
| 震動報警 | 脈沖警報或任何狀況警報 |
| 可視報警 | 2個閃光報警燈 |
| 傳感器類型 | 電化學,催化燃燒及可選紅外或PID |
| 校準 | 自動(單獨或與MicroDock II連接) |
| 數據記錄 | 所有發生事件(零點校正,校準標氣調整,氣體讀數,TWA, STEL,報警狀況,微處理器探測到的失誤) |
| 安全特性 | X5 及X5PID:Ⅱ1G Ga Exia ⅡC T4 ATEX; Ga Exia ⅡC T4 IECEx X5IR CO2:Ⅱ 2 G Ga Ex d ia ⅡC T4 ATEX; Ga Ex d ia ⅡC T4 IECEx 美國和加拿大認證:Class,Div.1 Gr.A,B,C,D T4. CAN/CSA C22.2 No.152 ;ANSI ISA S12.13.1 |
| 保修期 | 一年 |
儀器采購、咨詢聯系電話:010-82752485 ,82752463?